Ni-Cd Battery General Specifications
 |
 |
 |
Charging Method:
Standard charge: 0.1C x 15 hours
- To avoid overcharge, a timer is used to terminate the charging after 150% capacity input.
- The ambient temperature for 0.1C rate charging is 0¢XC to 45¢XC.
Fast charge: 1C x 1.2 hours
- With charging current over 0.5C rate, a joint use of dT or -£GV cut off is required. For dT control, a maximum allowable temperature rise is 0.8¢XC/min. Or if -£GV control is used, the maximum allowable voltage decrease is 5~10mV/cell. However, TCO device with cut off temperature at 45¢XC to 50¢XC should be used at the same time.
- Normally, the fully charged capacity under high rate charging is around 110 to 120% to the specified capacity. High rate overcharge without any control will ruin the battery.
- The ambient temperature for 1C rate charging is 10¢XC to 45¢XC.
|
|
|